Administrator Only Special Functions (cont):
Adjusting time ringing to Admin or Manager:
The unit will call the administrator and then the managers if the administrator doesn’t answer. Use this function to change how
long it will try each number before it rolls to the next number. If it reaches voicemail it will not distinguish that from someone
answering the phone.
Example: Change ring time to 15 seconds
Send the following SMS Command
*TETI#15
Example of Returned Message:
TETI:<15>
__________________________________________________________________________________
Turn on or off audible alarm at call box:
When the unit loses main power and is on back up power an alarm will sound at the call box. This function will turn that on or
off.
Turn O
*ALAC#1
Example of Returned Message:
ALAC-O
Turn OFF
*ALAC#0
Example of Returned Message:
ALAC-OFF
__________________________________________________________________________________
Changing the time the alarm will sound for:
You can adjust the amount of time the alarm will sound for. The alarm must be active - see above command. Default is 600
seconds.
Example: Sending the following SMS Command
*ALTM#00060 – The alarm will sound for 60 seconds.
Example of Returned Message:
ALTM:<00060>