Administrator Only Special Functions (cont):
Text report of gate opening or other event:
You can utilize input terminals 14 and/or 15 to text message the administrators when an event occurs by
using a 12V signal. Some common ways to do this is through a photo eye and a relay or through an output
terminal for a gate lock if it is on a model that puts out 12V DC. Basically you can get notified of any event
or two events as long as the event can be associated to something that generates a temporarily output of 12V
DC (1 to 4 seconds in length). For suggestion on how to accomplish this with your system please call Estate
Swing at 1-800-640-4283.
First, turn on the terminal you wish to use your event device with through SMS text:
Terminal 15 (Input 1) Terminal 14 (Input 2)
*CTR1#1 *CTR2#1
Returned message: INCTR1=ON Returned message: INCTR2=ON
Second, activate the TEXT notification for the terminal through SMS text:
Terminal 15 (Input 1) Terminal 14 (Input 2)
*CTC1#5 *CTC2#5
Returned message: CTC1=<5> Returned message: CTC2=<5>
__________________________________________________________________________
To turn this function off:
Terminal 15 (Input 1) Terminal 14 (Input 2)
*CTR1#0 *CTR2#0
Returned message: INCTR1=OFF Returned message: INCTR2=OFF
otification Message for Input 1:
OUT1<O>
otification Message for Input 2:
OUT2<O>