Fine tuning Limit Switches - Pull-to-Open
If the light does not go out before a physical limitation is reached, decrease the stroke length.
Open Position Adjustment
• Move the gate slowly to the Open
position (fig 1) until the FCA1 light
goes OFF (fig 2).
(FCA2 if working on the slave leaf of dual
opener)
• To increase the stroke length turn the
FCA screw:
COUNTER-CLOCKWISE (fig 3).
(make the gate open more)
• To decrease the stroke length turn the
FCA screw:
CLOCKWISE (fig 3).
(make the gate open less)
(fig 1)
(fig 2)
(fig 3)
Closed Position Adjustment
• Move the gate slowly to the Closed
position (fig 1) until the FCC1 light
goes OFF (fig 2).
(FCC2 if working on the slave leaf of dual
opener)
• To increase the stroke length turn the
FCC screw:
CLOCKWISE (fig 3).
(make the gate close more)
• To decrease the stroke length turn the
FCC screw:
COUNTER-CLOCKWISE (fig 3).
(make the gate close less)
(fig 1)
(fig 2)
(fig 3)
2.9